Products
  • Point of Care Devices Immunofluorescence Analyzer

    Point of Care Devices Immunofluorescence Analyzer

    Immunofluorescence Poct Quantitative Analyzer FI-1000 For POCT FIA (Fluorescence Immunoassay): 1. Extra incubator to provide Auto-incubating and Auto-alarm System. 2. Extra incubator to provide Isolated Incubation Environment to Eliminate Corruption. 3. Analysis in 10 seconds, CV < 10% 4. Extra incubator to provide Simultaneous incubation of 8 samples. 5. Whole blood samples for both PCT and hs-CRP.

  • Fully Automated CLIA Analyzer Chemiluminescence Immunoassay Device

    Fully Automated CLIA Analyzer Chemiluminescence Immunoassay Device

    Fully Automated CLIA Analyzer Chemiluminescence Immunoassay Device Self-developed antigens and self-manufactured antibodies that ensures minimized intra and inter batch difference Non-enzymatic chemiluminescence, long reagent stable time Acridinium ester as the marker, stable performance, without any light source, eliminating the influence of other factors. Sodium hydroxide (NaOH) and hydrogen peroxide(H2O2 ) are excitation substrate

  • Seven Minutes Acridinium Ester Chemiluminescence Immunoassay Analyzer

    Seven Minutes Acridinium Ester Chemiluminescence Immunoassay Analyzer

    Seven Minutes Acridinium Ester Flash Direct Chemiluminescence Immunoassay Plasma,whole blood and finger tip blood support Rapidity: The first testing finishes in only 7 minutes. Accuracy: direct chemiluminescence immunoassay provide accurate result and the linear correlation coefficient with Europe-America products ≥ 0.99. Precision: Within batch measurement repeatability: (CV, %) ≤ 5%

  • POCT Rapid Test Quantitative Immunoassay Analyzer

    POCT Rapid Test Quantitative Immunoassay Analyzer

    Poct Rapid Test Immunofluorescence Assay Analyzer Inflammation/Infection:PCT(whole blood), PCT (serum), hs-CRP+CRP (whole blood) Cardiovascular:NT-proBNP, cTnI/CK-MB/MYO, D-Dimer, cTnI,CK-MB, MYO Nephropathy: NAGL, Cys-c, mAlb, B2-MG Diabetes:HbA1c Gastrosis: PGI, PGII Upcoming: Vitamin D, T3/T4/TSH, mALb, β-HCG, SAA, Ferritin

  • FIA Meter Procalcitonin Test Fluorescence Immunoassay

    FIA Meter Procalcitonin Test Fluorescence Immunoassay

    For POCT FIA (Fluorescence Immunoassay 1. Whole blood samples for both PCT and hs-CRP. 2.Extra incubator to provide Auto-incubating and Auto-alarm System. 3. Extra incubator to provide Simultaneous incubation of 8 samples. 4. Extra incubator to provide Isolated Incubation Environment to Eliminate Corruption. 5.Analysis in 10 seconds, CV < 10%

  • Near Patient Test Device POC machine

    Near Patient Test Device POC machine

    1. Power: ~ 220v±22V 50HZ±1Hz 2. Volume: 214mm × 260mm × 143mm. 3. Input power: 50VA 4. Repeatability: CV≤10% 5. Principle:Immunochromatographic Methodology 6. LIS system: Support ASTM and HL7 7. Weight: 2.0kg 8. Incubating time: 5-15 minutes 9. Temperature range: 10~30℃ 10. Relative humidity: ≤80% 11. Atmospheric pressure: 70 ~ 106kpa

  • Chemiluminescence Immunoassay System CLIA Blood Diagnostic Equipment

    Chemiluminescence Immunoassay System CLIA Blood Diagnostic Equipment

    Chemiluminescence Immunoassay System CLIA Blood Diagnostic Equipment ​Power: AC220±22V 50±1Hz Input power: 500VA Repeatability: CV≤5% linear correlation coefficient (r)≥0.99 Volume:1180mm×770mm×785mm Weight: 150.0kg Use: Indoor Temperature range: 10~30ºC Relative humidity: ≤70% Atmospheric pressure: 85~106kpa

  • Fully Automatic Biochemistry Analyzer Blood Test Machine

    Fully Automatic Biochemistry Analyzer Blood Test Machine

    Fully Automatic Biochemistry Analyzer Blood Test Machine Light emitting principle: 1. Non-enzymatic chemiluminescence,long reagent stable time 2. Acridinium ester as the marker, stable performance,without any light source, 3. eliminating the influence of other factors. 4. Sodium hydroxide (NaOH) and hydrogen peroxide(H2O2 ) are excitation substrate.

  • Seven Minutes First Result Fast Chemiluminescence Immunoassay Analyzer

    Seven Minutes First Result Fast Chemiluminescence Immunoassay Analyzer

    Seven Minutes First Result Fast Chemiluminescence Immunoassay Analyzer 1. Rapidity: The first testing finishes in only 7 minutes. 2. Accuracy: direct chemiluminescence immunoassay provide accurate result and the linear 3. correlation coefficient with Europe-America products ≥ 0.99. 4. Precision: Within batch measurement repeatability: (CV, %) ≤ 5% 5. Sample testing: one sample, multiple indicators(ex. Myo, CK-MB, cTnI, etc.) diagnosis 6. Automation: automatic code scanner, and automated diagnosis.

  • Cardiovascular Poct Clia Chemiluminescence Immunoassay Analyzer

    Cardiovascular Poct Clia Chemiluminescence Immunoassay Analyzer

    Cardiovascular Poct Clia Chemiluminescence Immunoassay Analyzer 1. Rapidity: The first testing finishes in only 7 minutes. 2. Accuracy: direct chemiluminescence immunoassay provide accurate result and the linear 3. correlation coefficient with Europe-America products ≥ 0.99. 4. Precision: Within batch measurement repeatability: (CV, %) ≤ 5% 5. Sample testing: one sample, multiple indicators(ex. Myo, CK-MB, cTnI, etc.) diagnosis 6. Automation: automatic code scanner, and automated diagnosis.

  • Pct Procalcitonin Whole Blood Poct Chemiluminescence Immunoassay Analyzer

    Pct Procalcitonin Whole Blood Poct Chemiluminescence Immunoassay Analyzer

    Pct Procalcitonin Whole Blood Poct Chemiluminescence Immunoassay Analyzer 7 Min Poct Clia Small Size Chemiluminescence Immunology Biochemistry Analyzer

  • HS Ctni Poct Clia Chemiluminescence Immunoassay Small Size Ivd Analyzer

    HS Ctni Poct Clia Chemiluminescence Immunoassay Small Size Ivd Analyzer

    HS Ctni Poct Clia Chemiluminescence Immunoassay Small Size Ivd Analyzer 1. Rapidity: The first testing finishes in only 7 minutes. 2. Accuracy: direct chemiluminescence immunoassay provide accurate result and the linear 3. correlation coefficient with Europe-America products ≥ 0.99. 4. Precision: Within batch measurement repeatability: (CV, %) ≤ 5% 5. Sample testing: one sample, multiple indicators(ex. Myo, CK-MB, cTnI, etc.) diagnosis 6. Automation: automatic code scanner, and automated diagnosis. 7. Stability: The differences between the test results of the 4 hours and 8 hours after the instrument get in stable state and the test result when the instrument initially 8. 8. gets in stable state is smaller than 10%. 9. Exclusive techniques----- avoid red blood cells and other impurities interruption. 10. Superior R&D: hs-cTnI and H-FABP diagnosis is unique in China. 11. Thorough cardiovascular indicators testing. 12. Self-developed antigens and self-manufactured antibodies that ensures minimized intra and inter batch difference.

1234567>Total 182 Records
Please feel free to give your inquiry in the form below. We will reply you in 24 hours.