Products
  • Poct Lp-PLA2 Clia Chemiluminescence Immunoassay In Vitro Diagnostic Analyzer

    Poct Lp-PLA2 Clia Chemiluminescence Immunoassay In Vitro Diagnostic Analyzer

    High Precision Chemiluminescence Immunoassay Analyzer Seven Minutes Rapid Test Flash Direct Chemiluminescence Immunoassay Analyzer

  • Lp-PLA2 Poct Clia Chemiluminescence Immunoassay Analyzer

    Lp-PLA2 Poct Clia Chemiluminescence Immunoassay Analyzer

    Advantages Rapidity: The first testing finishes in only 7 minutes. Accuracy: direct chemiluminescence immunoassay provide accurate result and the linear correlation coefficient with Europe-America products ≥ 0.99. Precision: Within batch measurement repeatability: (CV, %) ≤ 5% Sample testing: one sample, multiple indicators(ex. Myo, CK-MB, cTnI, etc.) diagnosis Automation: automatic code scanner, and automated diagnosis. Stability: The differences between the test results of the 4 hours and 8 hours after the instrument get in stable state and the test result when the instrument initially gets in stable state is smaller than 10%. Exclusive techniques----- avoid red blood cells and other impurities interruption. Superior R&D: hs-cTnI and H-FABP diagnosis is unique in China. Thorough cardiovascular indicators testing.

  • Lipoprotein PLA2 Poct Clia Chemiluminescence Immunoassay Medical Ivd Instrument

    Lipoprotein PLA2 Poct Clia Chemiluminescence Immunoassay Medical Ivd Instrument

    Cardiovascular POCT Chemiluminescence Immunoassay Analyzer NT-proBNP、Lp-PLA2、 hs-cTnI 、CK-MB、 MYO、 H-FABP、 D-Dimer

  • Poct Lp-PLA2 Clia Chemiluminescence Immunoassay Ivd Medical Device

    Poct Lp-PLA2 Clia Chemiluminescence Immunoassay Ivd Medical Device

    Light Emiting Principle Non-enzymatic chemiluminescence, long reagent stable time Acridinium ester as the marker, stable performance, without any light source, eliminating the influence of other factors. Sodium hydroxide (NaOH) and hydrogen peroxide(H2O2 ) are excitation substrate.

  • Procalcitonin PCT POCT FIA Analyzer

    Procalcitonin PCT POCT FIA Analyzer

    1. Power: ~ 220v±22V 50HZ±1Hz 2. Volume: 214mm × 260mm × 143mm. 3. Input power: 50VA 4. Repeatability: CV≤10% 5. Principle:Immunochromatographic Methodology 6. LIS system: Support ASTM and HL7 7. Weight: 2.0kg 8. Incubating time: 5-15 minutes 9. Temperature range: 10~30℃ 10. Relative humidity: ≤80% 11. Atmospheric pressure: 70 ~ 106kpa

  • High sensitive CRP hs-CRP Fluorescence Immunoassay Analyzer

    High sensitive CRP hs-CRP Fluorescence Immunoassay Analyzer

    1. Power: ~ 220v±22V 50HZ±1Hz 2. Volume: 214mm × 260mm × 143mm. 3. Input power: 50VA 4. Repeatability: CV≤10% 5. Principle:Immunochromatographic Methodology 6. LIS system: Support ASTM and HL7 7. Weight: 2.0kg 8. Incubating time: 5-15 minutes 9. Temperature range: 10~30℃ 10. Relative humidity: ≤80% 11. Atmospheric pressure: 70 ~ 106kpa

  • Troponin I Fluorescence Immunoassay Analyzer

    Troponin I Fluorescence Immunoassay Analyzer

    1. Power: ~ 220v±22V 50HZ±1Hz 2. Volume: 214mm × 260mm × 143mm. 3. Input power: 50VA 4. Repeatability: CV≤10% 5. Principle:Immunochromatographic Methodology 6. LIS system: Support ASTM and HL7 7. Weight: 2.0kg 8. Incubating time: 5-15 minutes 9. Temperature range: 10~30℃ 10. Relative humidity: ≤80% 11. Atmospheric pressure: 70 ~ 106kpa

  • Tumor Markers Poct Fluorescence Immunoassay FIA Analyzer

    Tumor Markers Poct Fluorescence Immunoassay FIA Analyzer

    1. Power: ~ 220v±22V 50HZ±1Hz 2. Volume: 214mm × 260mm × 143mm. 3. Input power: 50VA 4. Repeatability: CV≤10% 5. Principle: Immunochromatographic Methodology 6. LIS system: Support ASTM and HL7 7. Weight: 2.0kg 8. Incubating time: 5-15 minutes 9. Temperature range: 10~30℃ 10. Relative humidity: ≤80% 11. Atmospheric pressure: 70 ~ 106kpa

  • D-dimer POCT FIA Immunoassay IVD Analyzer

    D-dimer POCT FIA Immunoassay IVD Analyzer

    1. Power: ~ 220v±22V 50HZ±1Hz 2. Volume: 214mm × 260mm × 143mm. 3. Input power: 50VA 4. Repeatability: CV≤10% 5. Principle:Immunochromatographic Methodology 6. LIS system: Support ASTM and HL7 7. Weight: 2.0kg 8. Incubating time: 5-15 minutes 9. Temperature range: 10~30℃ 10. Relative humidity: ≤80% 11. Atmospheric pressure: 70 ~ 106kpa

  • In Vitro Diagnostic Rapid Test Reader

    In Vitro Diagnostic Rapid Test Reader

    Our Advantages: For POCT FIA (Fluorescence Immunoassay): 1. Extra incubator to provide Auto-incubating and Auto-alarm System. 2. Extra incubator to provide Isolated Incubation Environment to Eliminate Corruption. 3. Analysis in 10 seconds, CV < 10% 4. Extra incubator to provide Simultaneous incubation of 8 samples. 5. Whole blood samples for both PCT and hs-CRP.

  • Laboratory Equipment Analysis Medical Fluorescence Immunoassay Analyzer

    Laboratory Equipment Analysis Medical Fluorescence Immunoassay Analyzer

    For POCT FIA ( Fluorescence Immunoassay ): 1. Extra incubator to provide Auto-incubating and Auto-alarm System 2. Analysis in 10 seconds, CV < 10% 3. Whole blood samples for both PCT and hs-CRP 4. Extra incubator to provide Simultaneous incubation of 8 samples 5. Extra incubator to provide Isolated Incubation Environment to Eliminate Corruption

  • Point Of Care Fluorescence Testing Equipment For Clinical Diabetic Analysis

    Point Of Care Fluorescence Testing Equipment For Clinical Diabetic Analysis

    Our Advantages: For POCT FIA (Fluorescence Immunoassay): 1. Extra incubator to provide Auto-incubating and Auto-alarm System. 2. Extra incubator to provide Isolated Incubation Environment to Eliminate Corruption. 3. Analysis in 10 seconds, CV < 10% 4. Whole blood samples for both PCT and hs-CRP. 5. Extra incubator to provide Simultaneous incubation of 8 samples.

1234>Total 45 Records