Poing of Care HbA1c Immunofluorescence Test Kit

Poing of Care HbA1c Immunofluorescence Test Kit

Brand :Norman

Product origin :China

Delivery time :In one month

Supply capacity :10000000/month

Hemoglobin A1c (HbA1c) is a result of the nonenzymatic attachment of a hexose molecule to the N-terminal amino acid of the hemoglobin molecule. The attachment of the hexose molecule occurs continually over the entire life span of the erythrocyte and is dependent on blood glucose concentration and the duration of exposure of the erythrocyte to blood glucose.

Diabetes Rapid Quantitative Poct HbA1c Fluorescence Immunoassay Test Kit:

hba1c rapid test


Clinical Information

Hemoglobin A1c (HbA1c) is a result of the nonenzymatic attachment of a hexose molecule to the N-terminal amino acid of the hemoglobin molecule. The attachment of the hexose molecule occurs continually over the entire life span of the erythrocyte and is dependent on blood glucose concentration and the duration of exposure of the erythrocyte to blood glucose. Therefore, the HbA1c level reflects the mean glucose concentration over the previous period (approximately 8-12 weeks, depending on the individual) and provides a much better indication of long-term glycemic control than blood and urinary glucose determinations. Diabetic patients with very high blood concentrations of glucose have from 2 to 3 times more HbA1c than normal individuals. 


Methodology: Fluorescence Immunoassay


Package:                                                                                           

Test card: Aluminum foil pouch 1pc/bag, desiccant

Package size: 25pcs/box


est Procedure:                                                                            

1. Open the Immune-fluorescence quantitative analyzer.

2. Check whether the batch number of IC card and reagent box is consistent, and then 

insert IC card into the instrument to get the curve we wanted.

3. Remove the test device from the protective pouch and place it on a flat surface. Draw

in 5μl of blood serum sample to the centrifugal tube, and dilute with 400μl of diluents. 

After gently mix the sample, add 90μl of diluted blood serum sample into the sample well. 

Place the test strip at room temperature for 5 minutes.

4. Insert the test card into the hole of immune-fluorescence quantitative analyzer, and click 

start, the instrument will scan the test card automatically.

5. Immune-fluorescence quantitative analyzer detects results automatically and calculates

 the content of Cys-C in the sample.

6. Specimens, used strip and transfer pipettes may be potentially infectious. Proper 

handling and disposal methods should be established by the laboratory direction in 

accordance with local regulations.


Please feel free to give your inquiry in the form below. We will reply you in 24 hours.