Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer
  • Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer Manufacturers, Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer Factory, Supply Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer
  • Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer Manufacturers, Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer Factory, Supply Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer
  • Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer Manufacturers, Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer Factory, Supply Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer
  • Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer Manufacturers, Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer Factory, Supply Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer
  • Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer Manufacturers, Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer Factory, Supply Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer
  • Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer Manufacturers, Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer Factory, Supply Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer

Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer

Brand :Norman

Product origin :China

Delivery time :Two weeks after payment

Supply capacity : 1000 units/per year

Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer
1. Chemiluminescence Analyzer
2. Self-developed antigens and self-manufactured antibodies that ensures minimized intra and inter batch difference.
3. Upgraded version, independent research and development.
4. Accurate testing result, more than 99% correlation with main stream Europe-Amefican products.

Fully Automatic Serum Plasma Chemiluminescence Immunoassay Analyzer:


85555555555555544444.jpg


Chemiluminescence Analyzer:                                                                

1. Self-developed antigens and self-manufactured antibodies that ensures minimized intra
and inter batch difference.

2. Upgraded version, independent research and development.

3. Accurate testing result, more than 99% correlation with main stream Europe-Amefican products.


Instrument Parameters                                                                                                           

1. Testing speed: 100 samples/ hour

2. Sample capacity: 36

3. Reagent capacity: 9

4. Refrigeration function for samples and reagents

5. Testing Mode: Batch, STAT, special samples

Structure of NORMAN Automated CLIA System:

791-201809041127017285.jpg                                                                                                          


1. Cuvette loading zone:

252cuvettes can be loaded one time and replaced at any time during testing.
Memorize numbers and location of cuvettes.


2. Reagent zone and sample zone:
Reagent zone: Power supply independent, magnetic beads levitation systems, refrigeration system is loadedin reagent area to keep reagent stable, the radio frequency identification technology is  adopted in kit information (calibration curve, time of validity, sample type).
Sample zone:Sample information can be entered manually or scanning recognition.
Three testing mode: Batch, STAT, special sample test
Sample editing mode: Hospital LIS System、Manual editing、Automatically software generating.


3. Sampling needle:
Automatic level detection,stirring mixing system,sampling needle made of titanium alloy material has good anti-collision function, single needle loads reagents, samples and magnetic beads. Inside and outside wall cleaning, on outer wall of needle is coated by Teflon, high polish,ensure cross-infection does not exceed 10-5.


4. 04.Incubation zone:
36.5±0.5ºC constant temperature incubation.
Incubation abnormity warning, magnetic separation components (independent magnetic separation).


5. Manipulator (exclusive design):
Mechanical grip: grab sample tube, avoid empty or partial catch.
Detection rod:automatic detection of sample tube,evaluate whether sample tube is located accurately.


6. Card reader:
Automatic identification of reagent Kit (type, curve, reagent position), no need manual code scanning.


07.  Magnetic separation components;
Magnetic separation device closely combines with sample tube, Nanjing Norman patented technology.


Specification:                                                

Power:

AC220±22V 50±1Hz

Input power:

500VA

Repeatability:

CV≤5%

Linear:

linear correlation    coefficient (r)≥0.99

Volume:

1180mm×770mm×785mm

Weight:

150.0kg

Use:

Indoor

Temperature range:

10~30ºC

Relative humidity:

≤70%

Atmospheric pressure:

85~106kpa



Package and Delivery:     

68844464645.jpg     

985556666666.jpg


Total Assays:

96526.jpg


About Norman:

1. Nanjing Norman Biological Technology Co., Ltd is dedicated to R&D and manufacturing of Fluorescence immunoassay analyzer (FIA) and automated chemiluminescence system (CLIA). Founded in 2008, Norman biological has been upholding the idea that R&D shapes future ,and concentration determines success. Ever since the beginning, Norman has been focusing on developing and manufacturing FIA and CLIA instruments and reagents.
2. Norman's manufacture center is located in the Yuhua District and owns an over 2,000m2 GMP-approved clean workshop. The R&D base, which is over 2,000m2 , is located in state-level new Jiangbei district. Now there are over 100 R&D engineers, 40% of which hold a PhD or master's degree.


1536743397(1)_副本.jpg


1536743426(1)_副本.jpg

                                                                                                              

Please feel free to give your inquiry in the form below. We will reply you in 24 hours.
close left right