Chemiluminescence Immunoassay Analyzer With Ce Approved
  • Chemiluminescence Immunoassay Analyzer With Ce Approved Manufacturers, Chemiluminescence Immunoassay Analyzer With Ce Approved Factory, Supply Chemiluminescence Immunoassay Analyzer With Ce Approved
  • Chemiluminescence Immunoassay Analyzer With Ce Approved Manufacturers, Chemiluminescence Immunoassay Analyzer With Ce Approved Factory, Supply Chemiluminescence Immunoassay Analyzer With Ce Approved
  • Chemiluminescence Immunoassay Analyzer With Ce Approved Manufacturers, Chemiluminescence Immunoassay Analyzer With Ce Approved Factory, Supply Chemiluminescence Immunoassay Analyzer With Ce Approved
  • Chemiluminescence Immunoassay Analyzer With Ce Approved Manufacturers, Chemiluminescence Immunoassay Analyzer With Ce Approved Factory, Supply Chemiluminescence Immunoassay Analyzer With Ce Approved
  • Chemiluminescence Immunoassay Analyzer With Ce Approved Manufacturers, Chemiluminescence Immunoassay Analyzer With Ce Approved Factory, Supply Chemiluminescence Immunoassay Analyzer With Ce Approved
  • Chemiluminescence Immunoassay Analyzer With Ce Approved Manufacturers, Chemiluminescence Immunoassay Analyzer With Ce Approved Factory, Supply Chemiluminescence Immunoassay Analyzer With Ce Approved

Chemiluminescence Immunoassay Analyzer With Ce Approved

Brand :NORMAN

Product origin :China

Delivery time :Two weeks after payment

Supply capacity :1000 units/per year

Chemiluminescence Immunoassay Analyzer With Ce Approved
1. Non-enzymatic chemiluminescence, long reagent stable time.
2. Acridinium ester as the marker, stable performance, without any light source.
3. Self-developed antigens and self-manufactured antibodies that ensures minimized intra and inter batch difference.
4. Upgraded version, independent research and development.Accurate testing result,
5. more than 99% correlation with main stream Europe-America products.

Chemiluminescence Immunoassay Analyzer With Ce Approved:


85555555555555544444.jpg      



1. Self-developed antigens and self-manufactured antibodies that ensures minimized intra and inter batch difference.
2. Upgraded version, independent research and development.Accurate testing result, 

more than 99% correlation with main stream Europe-America products.


About Norman:

1. Nanjing Norman Biological Technology Co., Ltd is dedicated to R&D and manufacturing of Fluorescence immunoassay analyzer (FIA) and automated chemiluminescence system (CLIA). Founded in 2008, Norman biological has been upholding the idea that R&D shapes future ,and concentration determines success. Ever since the beginning, Norman has been focusing on developing and manufacturing FIA and CLIA instruments and reagents.
2. Norman's manufacture center is located in the Yuhua District and owns an over 2,000m2 GMP-approved clean workshop. The R&D base, which is over 2,000m2 , is located in state-level new Jiangbei district. Now there are over 100 R&D engineers, 40% of which hold a PhD or master's degree.


1536743397(1)_副本.jpg


1536743426(1)_副本.jpg

59.jpg



Total Assays:

96526.jpg



Instrument Parameters:                                                                                                           

1. Testing speed: 100 samples/ hour

2. Sample capacity: 36

3. Reagent capacity: 9

4. Refrigeration function for samples and reagents

5. Testing Mode: Batch, STAT, special samples


Light emitting principle:                                                  

Non-enzymatic chemiluminescence, long reagent stable time

Acridinium ester as the marker, stable performance, without any light source, 

eliminating the influence of other factors.

Sodium hydroxide (NaOH) and hydrogen peroxide(H2O2 ) are excitation substrate.



Structure of NORMAN Automated CLIA System:            

791-201809041127017285.jpg

1. Cuvette loading zone:

252cuvettes can be loaded one time and replaced at any time during testing.
Memorize numbers and location of cuvettes.


2. Reagent zone and sample zone:
Reagent zone: Power supply independent, magnetic beads levitation systems, refrigeration system is loadedin reagent area to keep reagent stable, the radio frequency identification technology is  adopted in kit information (calibration curve, time of validity, sample type).
Sample zone:Sample information can be entered manually or scanning recognition.
Three testing mode: Batch, STAT, special sample test
Sample editing mode: Hospital LIS System、Manual editing、Automatically software generating.


3. Sampling needle:
Automatic level detection,stirring mixing system,sampling needle made of titanium alloy material has good anti-collision function, single needle loads reagents, samples and magnetic beads. Inside and outside wall cleaning, on outer wall of needle is coated by Teflon, high polish,ensure cross-infection does not exceed 10-5.


4. 04.Incubation zone:
36.5±0.5ºC constant temperature incubation.
Incubation abnormity warning, magnetic separation components (independent magnetic separation).


5. Manipulator (exclusive design):
Mechanical grip: grab sample tube, avoid empty or partial catch.
Detection rod:automatic detection of sample tube,evaluate whether sample tube is located accurately.


6. Card reader:
Automatic identification of reagent Kit (type, curve, reagent position), no need manual code scanning.


07.  Magnetic separation components;
Magnetic separation device closely combines with sample tube, Nanjing Norman patented technology.


Specification                                                                

01.  Power:

02.  AC220±22V 50±1Hz

03.  Input power:

04.  500VA

05.  Repeatability:

06.  CV≤5%

07.  Linear:

08.  linear correlation   coefficient   (r)≥0.99

09.  Volume:

10.  1180mm×770mm×785mm

11.  Weight:

12.  150.0kg

13.  Use:

14.  Indoor

15.  Temperature range:

16.  10~30ºC

17.  Relative humidity:

18.  ≤70%

19.  Atmospheric pressure:

20.  85~106kpa

                                                                      

Specification of main reagents:

378678765786587.jpg


69885555456454.jpg


Installation Requirements:

                                                                

Installation environment requirements:

1. Only for indoor installation and use.The installation environment shall be free of dust,mechanical vibration, or heavy noise, or power interference, with good ventilation.

2. Place the instrument on a solid and level table,   the table carrying capacity shall be no less  than 150kg (weight of the instrument)

3. For easy maintenance,leave some space around the instrument,which is easy to connect a variety of other components, also good for instrument cooling;

4. The instrument shall be far away from strong magnetic  fields, strong electric field, water source, corrosive fluids;  do not expose to strong direct light,  do not place near heat source. It is prohibitedto use the instrument near strong  radiation source; otherwise it may interfere with normal operation of the instrument.


Power Requirements:

1.  Power supply: AC220 ± 22V, frequency 50 ± 1Hz;

2.  Rated power: 500VA;
3.  Fuse sizes: F6A 250V, 5 * 20mm;
4. The instrument requires a properly grounded electrical outlet to provide the required power,do not use non-own power line;
5. The power outlet location shall allow sufficient space to facilitate plugging and unplugging the power line, do not put the analyzer in a location difficult to disconnect power.

Temperature, humidity and atmospheric pressure requirements

1. Work Ambient temperature: 10~30ºC, it is recommended to install air-conditioning;
2. Relative humidity ≤70%.
3. Atmospheric pressure: 85~106kpa.


Package and Delivery:     

68844464645.jpg     

985556666666.jpg

Get the latest price? We'll respond as soon as possible(within 12 hours)
close left right