Chemiluminescence Diagnosis Of Cardiovascular Disease Medical Products
  • Chemiluminescence Diagnosis Of Cardiovascular Disease Medical Products Manufacturers, Chemiluminescence Diagnosis Of Cardiovascular Disease Medical Products Factory, Supply Chemiluminescence Diagnosis Of Cardiovascular Disease Medical Products
  • Chemiluminescence Diagnosis Of Cardiovascular Disease Medical Products Manufacturers, Chemiluminescence Diagnosis Of Cardiovascular Disease Medical Products Factory, Supply Chemiluminescence Diagnosis Of Cardiovascular Disease Medical Products
  • Chemiluminescence Diagnosis Of Cardiovascular Disease Medical Products Manufacturers, Chemiluminescence Diagnosis Of Cardiovascular Disease Medical Products Factory, Supply Chemiluminescence Diagnosis Of Cardiovascular Disease Medical Products
  • Chemiluminescence Diagnosis Of Cardiovascular Disease Medical Products Manufacturers, Chemiluminescence Diagnosis Of Cardiovascular Disease Medical Products Factory, Supply Chemiluminescence Diagnosis Of Cardiovascular Disease Medical Products

Chemiluminescence Diagnosis Of Cardiovascular Disease Medical Products

Brand : Norman

Product origin : Nanjing

Delivery time :Two weeks after payment

Supply capacity : 1000 units/per year

Chemiluminescence Diagnosis Of Cardiovascular Disease Medical Products
Fully Automated Chemiluminescence immunoassay NRM 411:
Light emitting principle
Non-enzymatic chemiluminescence, long reagent stable time
Acridinium ester as the marker, stable performance, without any light source,
eliminating the influence of other factors.
Sodium hydroxide (NaOH) and hydrogen peroxide(H2O2 ) are excitation substrate.

Chemiluminescence Diagnosis Of Cardiovascular Disease Medical Products:


1536201866(1)_副本.jpg   


1. Self-developed antigens and self-manufactured antibodies that ensures minimized intra and inter batch difference.
2. Upgraded version, independent research and development.Accurate testing result, 
3. more than 99% correlation with main stream Europe-America products.


Total Assays:                                                                                                                        
1536054247(1).png


Instrument parameters:                                                 

1. Testing speed: 100 samples/ hour

2. Sample capacity: 36

3. Reagent capacity: 9

4. Refrigeration function for samples and reagents

5. Testing Mode: Batch, STAT, special samples.


Light emitting principle:                                                   

1. Non-enzymatic chemiluminescence, long reagent stable time

2. Acridinium ester as the marker, stable performance, without any light source, 

3. eliminating the influence of other factors.

4. Sodium hydroxide (NaOH) and hydrogen peroxide(H2O2 ) are excitation substrate.


Structure of NORMAN Automated CLIA System:

58155555.jpg            


1. Cuvette loading zone:

252cuvettes can be loaded one time and replaced at any time during testing.
Memorize numbers and location of cuvettes.


2. Reagent zone and sample zone:
Reagent zone: Power supply independent, magnetic beads levitation systems, refrigeration system is loadedin reagent area to keep reagent stable, the radio frequency identification technology is  adopted in kit information (calibration curve, time of validity, sample type).
Sample zone:Sample information can be entered manually or scanning recognition.
Three testing mode: Batch, STAT, special sample test
Sample editing mode: Hospital LIS System、Manual editing、Automatically software generating.


3. Sampling needle:
Automatic level detection,stirring mixing system,sampling needle made of titanium alloy material has good anti-collision function, single needle loads reagents, samples and magnetic beads. Inside and outside wall cleaning, on outer wall of needle is coated by Teflon, high polish,ensure cross-infection does not exceed 10-5.


4. 04.Incubation zone:
36.5±0.5ºC constant temperature incubation.
Incubation abnormity warning, magnetic separation components (independent magnetic separation).


5. Manipulator (exclusive design):
Mechanical grip: grab sample tube, avoid empty or partial catch.
Detection rod:automatic detection of sample tube,evaluate whether sample tube is located accurately.


6. Card reader:
Automatic identification of reagent Kit (type, curve, reagent position), no need manual code scanning.


07.  Magnetic separation components;
Magnetic separation device closely combines with sample tube, Nanjing Norman patented technology.


Specification:                                                                

01.  Power:

02.  AC220±22V 50±1Hz

03.  Input power:

04.  500VA

05.  Repeatability:

06.  CV≤5%

07.  Linear:

08.  linear correlation   coefficient   (r)≥0.99

09.  Volume:

10.  1180mm×770mm×785mm

11.  Weight:

12.  150.0kg

13.  Use:

14.  Indoor

15.  Temperature range:

16.  10~30ºC

17.  Relative humidity:

18.  ≤70%

19.  Atmospheric pressure:

20.  85~106kpa


Specification of main reagents:                                                                      

23_副本.jpg

Installation Requirements:

                                                                

Installation environment requirements:

1. Only for indoor installation and use.The installation environment shall be free of dust,mechanical vibration, or heavy noise, or power interference, with good ventilation.

2. Place the instrument on a solid and level table,   the table carrying capacity shall be no less  than 150kg (weight of the instrument)

3. For easy maintenance,leave some space around the instrument,which is easy to connect a variety of other components, also good for instrument cooling;

4. The instrument shall be far away from strong magnetic  fields, strong electric field, water source, corrosive fluids;  do not expose to strong direct light,  do not place near heat source. It is prohibitedto use the instrument near strong  radiation source; otherwise it may interfere with normal operation of the instrument.


Power Requirements:

1.  Power supply: AC220 ± 22V, frequency 50 ± 1Hz;

2.  Rated power: 500VA;
3.  Fuse sizes: F6A 250V, 5 * 20mm;
4. The instrument requires a properly grounded electrical outlet to provide the required power,do not use non-own power line;
5. The power outlet location shall allow sufficient space to facilitate plugging and unplugging the power line, do not put the analyzer in a location difficult to disconnect power.

Temperature, humidity and atmospheric pressure requirements

1. Work Ambient temperature: 10~30ºC, it is recommended to install air-conditioning;
2. Relative humidity ≤70%.
3. Atmospheric pressure: 85~106kpa.


Package and Delivery:          

Medical Laboratory Test Equipment Biochemistry Analyzer

Medical Laboratory Test Equipment Biochemistry Analyzer

About us:                                                                                                        
Nanjing Norman Biological Technology Co.,Ltd is dedicated to R&D and manufacturing
of Immunofluorescence and automated  chemiluminescence system. Founded in  2008,
Norman biological has been upholding the idea  that  R&D shapes future,concentration
determines success.Now there are over 100 R&D engineers,40% of which hold a PhD
or master's degree. An over 30,000m2 global R&D center is in construction, and  will  hold more than1,000 R&D engineers in the future.

Nanjing-Norman-Biological-Technology-Co-Ltd- (8).jpg

Please feel free to give your inquiry in the form below. We will reply you in 24 hours.
close left right