Cardiac Chemiluminesence Immonoassay Creatine Kinase Isoenzyme Reagent

Cardiac Chemiluminesence Immonoassay Creatine Kinase Isoenzyme Reagent

Brand :Norman

Product origin :Nanjing

Delivery time :Two weeks after payment

Supply capacity :100,000 units/month

CK-MB Clinical Significance:
1. Began to rise after 3-8 hrs
2. Reach peak value after 8-24hrs
3. Return to normal value after 3 days
4. Early diagnosis of AMI and risk stratification .
5. Most valuable markers of non-ST-segment elevation MI
6. CK-MB mainly exists inmyocardium. Content of CK-MB in serum is sensitive and specific to myocardial damage.
7.CK-BB Mainly exists in brain, prostate,intestine,lung,bladder,uterus,placenta,and goiter.

Chemiluminesence Immonoassay Ck MB (Creatine Kinase Isoenzyme) Test Reagent:

Methodology: Chemiluminescence immunoassay


Product show:

Chemiluminesence-Immonoassay-Ck-MB-Creatine-Kinase-Isoenzyme-Test-Reagent.jpg                                                                                          

CK-MB:                                                                                                           

1. Registration No: Jiangsu food and drug administration 2014-2400618.
2. Important indicator for diagnosis of AMI.
3. Analyze  re-infarction and infarction size.

Clinical Significance:                                                                                       
1. Began to rise after 3-8 hrs
2. Reach peak value after 8-24hrs  
3. Return to normal value after 3 days
4. Early diagnosis of AMI and risk stratification .
5. Most valuable markers of non-ST-segment elevation MI
6. CK-MB  mainly exists inmyocardium. Content of CK-MB in serum is sensitive and specific to myocardial damage.
7.CK-BB Mainly exists in brain, prostate,intestine,lung,bladder,uterus,placenta,and goiter.
CK-MM  Mainly exists in skeletal muscle and myocardium.

Product advantage:                                                                                         
1. High sensitivity: 0.4ng/ml.
2. High accuracy : 99% result correlation with similar product of Siemens ADVIA Centaur.
3. Wide linear range: 0.4-300ng/ml.


Performance analysis                                                                                   

Correlation analysis between NORMAN CK-MB and Siemens ADVIACentaur CK-MB

Changes of myocardial markers after AMI attack

1. Myoglobin

2. Troponin(Large area infarction, e.g.STEMI

3. Troponin(Small area infarction  e.g.NSTEMI

4. CK-MB


Company profile:                                                                                             

Nanjing Norman Biological Technology Co., Ltd is dedicated to R&D and manufacturing of automated chemiluminescence system. Founded in 2008, Norman biological has been upholding the idea that R&D shapes future ,and concentration determines success. Ever since the beginning,Norman has been focusing on developing and manufacturing  chemiluminescence and immunofluorescence  reagents.


6415.jpg



Agent Wanted: If you are interested in working with us, please feel free to contact. 

61.jpg

Why Us:                                                                                                                

1. Manufacturer and Exporter for nearly 10 years with self R&D Research Center;

2. Professional After-Sale service with On-site support worldwide; 
3. CE/ISO13485/SGS/RoHS Certifications!


OEM and ODM are available !


Please feel free to give your inquiry in the form below. We will reply you in 24 hours.