Acridinium Ester Chemiluminescence Immunoassay Instrument
  • Acridinium Ester Chemiluminescence Immunoassay Instrument Manufacturers, Acridinium Ester Chemiluminescence Immunoassay Instrument Factory, Supply Acridinium Ester Chemiluminescence Immunoassay Instrument
  • Acridinium Ester Chemiluminescence Immunoassay Instrument Manufacturers, Acridinium Ester Chemiluminescence Immunoassay Instrument Factory, Supply Acridinium Ester Chemiluminescence Immunoassay Instrument
  • Acridinium Ester Chemiluminescence Immunoassay Instrument Manufacturers, Acridinium Ester Chemiluminescence Immunoassay Instrument Factory, Supply Acridinium Ester Chemiluminescence Immunoassay Instrument
  • Acridinium Ester Chemiluminescence Immunoassay Instrument Manufacturers, Acridinium Ester Chemiluminescence Immunoassay Instrument Factory, Supply Acridinium Ester Chemiluminescence Immunoassay Instrument
  • Acridinium Ester Chemiluminescence Immunoassay Instrument Manufacturers, Acridinium Ester Chemiluminescence Immunoassay Instrument Factory, Supply Acridinium Ester Chemiluminescence Immunoassay Instrument

Acridinium Ester Chemiluminescence Immunoassay Instrument

Brand :Norman

Product origin : Nanjing

Delivery time :Two weeks after payment

Supply capacity :1000 units/per year

Acridinium Ester Chemiluminescence Immunoassay Instrument
Automation Chemiluminescence immunoassay
Light emitting principle
Non-enzymatic chemiluminescence, long reagent stable time
Acridinium ester as the marker, stable performance, without any light source,
eliminating the influence of other factors.
Sodium hydroxide (NaOH) and hydrogen peroxide(H2O2 ) are excitation substrate.

Acridinium Ester Chemiluminescence Immunoassay Instrument

1536201866(1)_副本.jpg


Self-developed antigens and self-manufactured antibodies that ensures minimized intra and inter batch difference.
Upgraded version, independent research and development.Accurate testing result, 
more than 99% correlation with main stream Europe-America products.


Total Assays  


Instrument parameters                                                 

Testing speed: 100 samples/ hour

Sample capacity: 36

Reagent capacity: 9

Refrigeration function for samples and reagents

Testing Mode: Batch, STAT, special samples.


Light emitting principle                                                   

Non-enzymatic chemiluminescence, long reagent stable time

Acridinium ester as the marker, stable performance, without any light source, 

eliminating the influence of other factors.

Sodium hydroxide (NaOH) and hydrogen peroxide(H2O2 ) are excitation substrate.


Structure of NORMAN Automated CLIA System            

Medical Laboratory Test Equipment Biochemistry Analyzer

01.  Cuvette loading zone

252cuvettes can be loaded one time and replaced at any time during testing.
Memorize numbers and location of cuvettes.

02.  Reagent zone and sample zone
Reagent zone:
Power supply independent, magnetic beads levitation systems, refrigeration system is loadedin reagent area to keep reagent stable, the radio frequency identification technology is  adopted in kit information (calibration curve, time of validity, sample type).
Sample zone
Sample information can be entered manually or scanning recognition
Three testing mode:
Batch, STAT, special sample test
Sample editing mode:
Hospital LIS System
Manual editing
Automatically software generating

03.  Sampling needle
Automatic level detection,stirring mixing system,sampling needle made of titanium alloy material has good anti-collision function, single needle loads reagents, samples and magnetic beads. Inside and outside wall cleaning, on outer wall of needle is coated by Teflon, high polish,ensure cross-infection does not exceed 10-5

04.  04.Incubation zone
36.5±0.5ºC constant temperature incubation.
Incubation abnormity warning, magnetic separation components (independent magnetic separation).

05.  Manipulator (exclusive design)
Mechanical grip: grab sample tube, avoid empty or partial catch.
Detection rod:automatic detection of sample tube,evaluate whether sample tube is located accurately.

06.  Card reader
Automatic identification of reagent Kit (type, curve, reagent position), no need manual code scanning.

07.  Magnetic separation components
Magnetic separation device closely combines with sample tube, 


Specification                                                                

01.  Power:

02.  AC220±22V 50±1Hz

03.  Input power:

04.  500VA

05.  Repeatability:

06.  CV≤5%

07.  Linear:

08.  linear correlation   coefficient   (r)≥0.99

09.  Volume:

10.  1180mm×770mm×785mm

11.  Weight:

12.  150.0kg

13.  Use:

14.  Indoor

15.  Temperature range:

16.  10~30ºC

17.  Relative humidity:

18.  ≤70%

19.  Atmospheric pressure:

20.  85~106kpa

                                                                      

Specification of main reagents                                               

Medical Laboratory Test Equipment Biochemistry Analyzer

Medical Laboratory Test Equipment Biochemistry Analyzer

Principle of measurement                                                    

Automated chemiluminescence assay consists of two parts, automatic reaction system and chemiluminescent assay system.  Automated  reaction  system  is the process to  indirect specifically bind the luminescent markers to the solid phase carrier through incubation and magnetic separation method. Chemiluminescence assay system is the process that when luminescent markers move from the acidic environment suddenly to the alkaline environment, oxidized by the hydrogen peroxide then it emits photons with maximum wavelength 430nm, which is then captured by the photomultiplier. The system utilizes acridinium ester and its derivatives as luminescent markers, luminescent through injecting excimer,and complete within a few seconds, belonging to flash type  chemiluminescence. Acridine ester and its derivatives as luminescent markers for measuring analysis has advantages including simple, fast, no necessary catalyst, good stability, low non-
specific binding and high sensitivity in the reaction,which is a new-type and efficient compound.


Installation Requirements                                                               


Temperature, humidity and atmospheric pressure requirements

1. Work Ambient temperature: 10~30ºC, it is recommended to install air-conditioning;
2. Relative humidity ≤70%.
3. Atmospheric pressure: 85~106kpa.


Package and Delivery          

Medical Laboratory Test Equipment Biochemistry Analyzer

Medical Laboratory Test Equipment Biochemistry Analyzer

About us                                                                     
Nanjing Norman Biological Technology Co.,Ltd is dedicated to R&D and manufacturing of Immunofluorescence and automated chemiluminescence system. Founded in  2008, Norman biological has been upholding the idea that  R&D shapes future,concentration determines success.Now there are over 100 R&D engineers,40% of which hold a PhD or master's degree.